Published February 1979
| Version v1
Report
Restricted
The detection of inhomogeneities in liquid metals by inductive flow measurement
Description
Gas bubbles in the liquid metal flow are detectable as negative pulses in the output signal of an inductive flowmeter. In model experiments and calculations the influence of size and path of single bubbles on these pulses was analyzed. The rms-value of a noise signal, generated by many bubble pulses, is proportional to the void fraction and inversely proportional to the square root of the pulse rate. The efficiency of an inductive detection system for sodium-to-water steam generators was investigated using the method of the statistical decision theory. (author)
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Additional titles
- Original title (German)
- Detektion von Inhomogenitaeten in Fluessigmetallen mittels induktiver Stroemungsmessung
Publishing Information
- Imprint Pagination
- 62 p.
- Report number
- ZfK--387
INIS
- Country of Publication
- German Democratic Republic
- Country of Input or Organization
- German Democratic Republic
- INIS RN
- 10487964
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Thesis
- Descriptors DEI
- BUBBLES; FLOW MODELS; FLOWMETERS; LEAKS; LIQUID METALS; PULSES; REACTOR NOISE; SODIUM
- Descriptors DEC
- ALKALI METALS; ELEMENTS; FLUIDS; LIQUIDS; MATHEMATICAL MODELS; MEASURING INSTRUMENTS; METALS