Published November 1, 2019 | Version v1
Journal article

Tensile test analysis of cold-formed column in channel profile

  • 1. Department of Civil Engineering, State University of Malang (Indonesia)

Description

This study analyzes the joint capacity of cold-rolled steel frame structure for multi-level buildings to withstand axial loads. The column frame joint structures will be modeled, analyzed and tested. In this paper, the study is about cold-formed channel profile that will be tensile tested with 2 variations of the joint. The research objectives are (1) to determine the stress and strain, (2) the damage pattern. The test object is modeled using FEM with a scale of 1: 1 and the loading used is linear static loading. Simulation with FEM use a trial and error method by entering the parameters obtained. The draft and design of channel profiles using cold rolled steel material refers to several guidelines including SNI-7971-2013 on Cold Formed Steel Structures. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1757-899X/669/1/012049

Additional details

Publishing Information

Journal Title
IOP Conference Series. Materials Science and Engineering (Online)
Journal Volume
669
Journal Issue
1
Journal Page Range
[6 p.]
ISSN
1757-899X

Conference

Title
2. International Conference on Green Civil and Environmental Engineering
Dates
4-6 Sep 2019
Place
Malang (Indonesia)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
54075741
Subject category
S36: MATERIALS SCIENCE; S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPUTERIZED SIMULATION; DESIGN; ERRORS; RECOMMENDATIONS; STATIC LOADS; STEELS; STRESSES
Descriptors DEC
ALLOYS; CARBON ADDITIONS; IRON ALLOYS; IRON BASE ALLOYS; SIMULATION; TRANSITION ELEMENT ALLOYS