Tensile test analysis of cold-formed column in channel profile
Creators
- 1. Department of Civil Engineering, State University of Malang (Indonesia)
Description
This study analyzes the joint capacity of cold-rolled steel frame structure for multi-level buildings to withstand axial loads. The column frame joint structures will be modeled, analyzed and tested. In this paper, the study is about cold-formed channel profile that will be tensile tested with 2 variations of the joint. The research objectives are (1) to determine the stress and strain, (2) the damage pattern. The test object is modeled using FEM with a scale of 1: 1 and the loading used is linear static loading. Simulation with FEM use a trial and error method by entering the parameters obtained. The draft and design of channel profiles using cold rolled steel material refers to several guidelines including SNI-7971-2013 on Cold Formed Steel Structures. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1757-899X/669/1/012049Additional details
Identifiers
Publishing Information
- Journal Title
- IOP Conference Series. Materials Science and Engineering (Online)
- Journal Volume
- 669
- Journal Issue
- 1
- Journal Page Range
- [6 p.]
- ISSN
- 1757-899X
Conference
- Title
- 2. International Conference on Green Civil and Environmental Engineering
- Dates
- 4-6 Sep 2019
- Place
- Malang (Indonesia)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54075741
- Subject category
- S36: MATERIALS SCIENCE; S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COMPUTERIZED SIMULATION; DESIGN; ERRORS; RECOMMENDATIONS; STATIC LOADS; STEELS; STRESSES
- Descriptors DEC
- ALLOYS; CARBON ADDITIONS; IRON ALLOYS; IRON BASE ALLOYS; SIMULATION; TRANSITION ELEMENT ALLOYS