Published 1998 | Version v1
Miscellaneous Open

Bases for calibration of whole body counters using anthropomorphic physical simulators

Description

The quantification of radionuclides in the human body can be carried out through in vivo measurements performed in facilities generically called whole body counters. The calibration of such units is usually done by using physical anthropomorphic phantoms, which can be defined as artificial structures with geometrical characteristics and attenuation properties similar to the living tissues. This work presents the development of the phantoms necessary to the monitoring of the internal contamination by the radionuclides manipulated in Brazil. It also presents the procedures for the calibration of the detectors used for the in vivo measurements. The developed phantoms are applied in the determination of radionuclides deposited in specific organs, such as Th-232 and Am-241 in the lungs and skull, isotopes of iodine in the thyroid and photon emitters in the energy range from 100 to 3000 keV in the whole body. (author)

Files

43130643.pdf

Files (11.0 MB)

Name Size Download all
md5:82fe2f54121d360c633d2c02c55cf0f0
11.0 MB Preview Download

Additional details

Additional titles

Original title (Portuguese)
Bases para a calibracao de contadores de corpo inteiro utilizando simuladores fisicos antropomorficos

Publishing Information

Imprint Pagination
172 p.
Report number
INIS-BR--12361