Published May 1988 | Version v1
Journal article

A double grid position sensitive avalanche chamber

  • 1. Academia Sinica, Lanzhou, GS (China). Inst. of Modern Physics

Description

A double grid position sensitive avalanche chamber (DGAC) has been developed. Its sensitive area is 250 x 200 mm2. The properties of the DGAC were tested in flowing isobutylene gas at a pressure of 360 Pa. The position resolution of 4 mm in both x and y coordinates and the time resolution of 290 ps are obtained for 252Cf fission fragment source

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
8
Journal Issue
3
Series
Nucl. Electron. Detect. Technol.
Journal Page Range
145-150
ISSN
0258-0934
CODEN
HDYUE