Experimental investigations on the weakening of pulsed X-radiation by contrast media
Description
In order to be able to carry out a videodensitometry simultaneously with the cineangiocardiography with pulsed X-rays, the weakening of the X-radiation by contrast media is more closely examined and a calibration of the amplitudes is carried out. The determination of the extinction curves for different parts of the X-ray pulses show that under unfavourable conditions (high voltage, low tube current, no Cu filtration) the spectrum is displaced to larger wavelengths, white an influence on the weakness coefficient only occurs after the intensity has fallen to 10% of the impulse maximum. On the other hand, the quantity depedence of the extinction coefficient is significant. The densitometry simulations performed with a digital computer using empirically gained calibration curves show that a quantitative densitometry is possible even if the Lambert-Beer law is not valid. (ORU/LH)
Abstract (German)
Um neben der Kineangiokardiographie mit gepulster Roentgenstrahlung gleichzeitig eine Videodensitometrie durchfuehren zu koennen, wird die Schwaechung der Roentgenstrahlung durch Kontrastmittel naeher untersucht und eine Kalibrierung der Amplituden vorgenommen. Die Bestimmung der Extinktionskurven fuer verschiedene Teile der Roentgenimpulse zeigt, dass sich unter unguenstigen Strahlenbedingungen (hohe Spannung, niedriger Roehrenstrom, keine Cu-Filterung) das Spektrum zu groesseren Wellenlaengen verschiebt, ein Einfluss auf den Schwaechungskoeffizient jedoch erst auftritt, nachdem die Intensitaet auf 10% des Impulsmaximums abgefallen ist. Von Bedeutung ist dagegen die Mengenabhaengigkeit des Extinktionskoeffizienten. Die mit einem Digitalrechner unter Verwendung empirisch gewonnener Eichkurven durchgefuehrte Densitometrie-Simulationen zeigen, dass auch ohne Gueltigkeit des Lambert-Beerschen Gesetzes eine quantitative Densitometrie moeglich ist. (ORU)Additional details
Additional titles
- Original title (German)
- Experimentelle Untersuchungen ueber die Schwaechung gepulster Roentgenstrahlung durch Kontrastmittel
Publishing Information
- Imprint Pagination
- 42 p.
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 7257647
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES; S60: APPLIED LIFE SCIENCES;
- Resource subtype / Literary indicator
- Thesis, Non-conventional Literature
- Descriptors DEI
- ABSORPTION; BIOMEDICAL RADIOGRAPHY; BLOOD VESSELS; CALIBRATION; CONTRAST MEDIA; FEASIBILITY STUDIES; IMAGES; PULSE TECHNIQUES
- Descriptors DEC
- CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; MEDICINE
Optional Information
- Notes
- 15 figs.; 30 refs. Available from ZAED.