Published October 2000
| Version v1
Journal article
On the measurement of low fluid velocity due to natural convection
- 1. Science Univ. of Tokyo, Dept. of Mechanical Engineering, Noda, Chiba (Japan)
- 2. Yamagata 3M Limited, Yamagata (Japan)
- 3. Science Univ. of Tokyo (Japan). Faculty of Science
Description
The measurement of low fluid velocity due to natural convection is tried in a vertical annulus by a method using a tracer of heated air (a thermal pulse technique). This technique is firstly used for measuring the velocities from 0.1 m/s to 1.0 m/s in laminar forced convective flows in a vertical circular pipe, and its availability is verified. Secondly, the method is applied to natural convective flows in the vertical annulus at the Grashof numbers from 103 to 104. The measured velocity distributions in the radial direction are in a relatively good agreement with those of numerical computations. (author)
Additional details
Publishing Information
- Journal Title
- Nippon Kikai Gakkai Ronbunshu, B Hen
- Journal Volume
- 66
- Journal Issue
- 650
- Journal Page Range
- p. 2748-2751
- ISSN
- 0387-5016
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 32003792
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- BENCH-SCALE EXPERIMENTS; DETECTION; FLUID FLOW; HEATERS; LAMINAR FLOW; LMFBR TYPE REACTORS; NATURAL CONVECTION; PULSE TECHNIQUES; REYNOLDS NUMBER; VELOCIMETERS; WIRES
- Descriptors DEC
- BREEDER REACTORS; CONVECTION; ENERGY TRANSFER; EPITHERMAL REACTORS; FAST REACTORS; FBR TYPE REACTORS; FLUID FLOW; HEAT TRANSFER; LIQUID METAL COOLED REACTORS; MASS TRANSFER; MEASURING INSTRUMENTS; REACTORS
Optional Information
- Notes
- 3 refs., 9 figs., 1 tab.