Segmented wire ion chambers (SWICs) used as proton beam position/profile detectors in the fixed target beamlines at Fermilab
Creators
- 1. Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, Illinois 60510 (United States)
Description
Segmented Wire Ion Chambers have been used at Fermilab since 1972 to monitor the profile of the proton beams in the various beamlines. Many modifications and improvements have been made since that time. SWICs are presently used to display beam profiles at intensities from 106 to over 1013 particles/sec
Additional details
Identifiers
- DOI
- 10.1063/1.55066;
Publishing Information
- Journal Title
- AIP Conference Proceedings
- Journal Volume
- 422
- Journal Issue
- 1
- Journal Page Range
- p. 409-413
- ISSN
- 0094-243X
- CODEN
- APCPCS
Conference
- Title
- School on instrumentation in elementary particle physics
- Dates
- 7-19 Jul 1997
- Place
- Leon (Mexico)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 40056748
- Subject category
- S43: PARTICLE ACCELERATORS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAM MONITORING; BEAM MONITORS; BEAM PROFILES; FERMILAB; MODIFICATIONS; MULTIWIRE IONIZATION CHAMBERS; PROTON BEAMS
- Descriptors DEC
- BEAMS; IONIZATION CHAMBERS; MEASURING INSTRUMENTS; MONITORING; MONITORS; NATIONAL ORGANIZATIONS; NUCLEON BEAMS; PARTICLE BEAMS; RADIATION DETECTORS; US DOE; US ORGANIZATIONS
Optional Information
- Contract/Grant/Project number
- Contract AC02-76CH0300
- Notes
- (c) 1998 American Institute of Physics.