Published December 19, 1986
| Version v1
Report
Restricted
Hydraulic transients for loss of coolant accidents
Description
This paper discusses calculations related to hydraulics in a loss of coolant reactor accident. Earlier calculations ignored the effect of emergency coolant injection. Present results show that if the ECS flow is considered, reactor coolant flow is maintained for much longer periods. A computer program used to carry out the calculations is included in this report
Availability note (English)
Available from NTIS, PC A03/MF A01; 1 as DE88005555.
Files
Additional details
Publishing Information
- Imprint Pagination
- 25 p.
- Report number
- RTR--2424-Del.Ver
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19073550
- Subject category
- S99: GENERAL AND MISCELLANEOUS;
- Descriptors DEI
- D CODES; HYDRAULICS; LOSS OF COOLANT; SAFETY ENGINEERING; TRANSIENTS
- Descriptors DEC
- ACCIDENTS; COMPUTER CODES; REACTOR ACCIDENTS
Optional Information
- Notes
- Portions of this document are illegible in microfiche products.