Published April 2018 | Version v1
Book

Converting a Baseload Designed Nuclear Power Plant for Flexible Operation: French Operating Experience. Annex II

Creators

Description

This annex provides details of French efforts towards converting a nuclear power plant that is optimized for baseload operation to perform flexible operation. This case study1 illustrates the experience gained in the design changes and for operation, including the considerations in decision making for flexible operation of nuclear generating units and establishing specific capabilities for flexibility in baseload optimized plants by design and operational modifications.

Part of:
Non-baseload Operation in Nuclear Power Plants: Load Following and Frequency Control Modes of Flexible Operation

Additional details

Publishing Information

Publisher
IAEA
Imprint Place
Vienna (International Atomic Energy Agency (IAEA))
ISBN
978-92-0-110816-6
Imprint Title
Non-baseload Operation in Nuclear Power Plants: Load Following and Frequency Control Modes of Flexible Operation
Imprint Pagination
190 p.
Journal Issue
no. NP-T-3.23
Series
IAEA Nuclear Energy Series
Journal Page Range
p. 130-137
ISSN
1995-7807

Optional Information

Notes
4 refs., 3 figs..
Secondary number(s)
STI/PUB--1756