Published November 1982 | Version v1
Journal article

Influence of the sample radius and irradiated zone width on the defocusing phenomenon in the Schulz technique

Creators

  • 1. Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

Description

The influence of the sample radius and irradiated zone width on the defocusing phenomenon is analysed by means of theoretical expressions which result from the convolution of a Cauchy fitting of the diffraction peak on the receiving plane. For the usual sample radius (about 12 mm) an irradiated zone width which is larger than expected may be used without any additional intensity loss. For a small sample radius (e.g. 4 mm), defocusing is less pronounced when a 6 mm irradiated zone width is used. (0002) and [10-10] pole figures of Zry-4 (a zirconium-based alloy) samples (obtained from a cladding tube of a pressurized water reactor fuel element) illustrate the results. (Auth.)

Additional details

Publishing Information

Journal Title
Mater. Sci. Eng.
Journal Volume
56
Journal Issue
2
Series
Mater. Sci. Eng.
Journal Page Range
135-141
ISSN
0025-5416

INIS

Country of Publication
Switzerland
Country of Input or Organization
Switzerland
INIS RN
14731338
Subject category
S36: MATERIALS SCIENCE;
Descriptors DEI
DIFFRACTION METHODS; INTEGRALS; SCHULZ METHOD; TEXTURE; X-RAY DIFFRACTION; ZIRCALOY 4
Descriptors DEC
ALLOYS; COHERENT SCATTERING; DIFFRACTION; SCATTERING; TIN ALLOYS; TRANSITION ELEMENT ALLOYS; ZIRCALOY; ZIRCONIUM ALLOYS; ZIRCONIUM BASE ALLOYS