Published 1984 | Version v1
Book

Rancho Seco ''light bulb incident''

Creators

  • 1. Rancho Seco Unit One, Sacramento Municipal Utility District, Sacramento, CA

Description

Reactor tripped on high pressure due to a loss of feedwater, initiated by a fault on a Non-Nuclear Instrumentation Power supply. Considerable control room indication was lost. Safety Features actuated on low pressure following the reactor trip. When power was restored an hour and a quarter later, temperature had dropped to 2850F. The Reactor Coolant System was outside of its allowable pressure/temperature curve

Additional details

Publishing Information

Publisher
Plenum Press.
Imprint Place
New York, NY (USA)
Imprint Title
Anticipated and abnormal plant transients in light water reactors, Vol. 1
Journal Page Range
p. 143-151.

Conference

Title
Anticipated and abnormal plant transients in light water reactors conference.
Dates
26-29 Sep 1983.
Place