CT- and MRI-based volumetry of resected liver specimen: Comparison to intraoperative volume and weight measurements and calculation of conversion factors
Creators
- 1. Institute of Diagnostic Radiology, Department of Radiology, University Hospital of Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)
- 2. Department of Visceral Surgery, University Hospital of Zurich (Switzerland)
- 3. Institute for Radiology and Radiodiagnostics, City Hospital Triemli, Zurich (Switzerland)
Description
Objective: To compare virtual volume to intraoperative volume and weight measurements of resected liver specimen and calculate appropriate conversion factors to reach better correlation. Methods: Preoperative (CT-group, n = 30; MRI-group, n = 30) and postoperative MRI (n = 60) imaging was performed in 60 patients undergoing partial liver resection. Intraoperative volume and weight of the resected liver specimen was measured. Virtual volume measurements were performed by two readers (R1,R2) using dedicated software. Conversion factors were calculated. Results: Mean intraoperative resection weight/volume: CT: 855 g/852 mL; MRI: 872 g/860 mL. Virtual resection volume: CT: 960 mL(R1), 982 mL(R2); MRI: 1112 mL(R1), 1115 mL(R2). Strong positive correlation for both readers between intraoperative and virtual measurements, mean of both readers: CT: R = 0.88(volume), R = 0.89(weight); MRI: R = 0.95(volume), R = 0.92(weight). Conversion factors: 0.85(CT), 0.78(MRI). Conclusion: CT- or MRI-based volumetry of resected liver specimen is accurate and recommended for preoperative planning. A conversion of the result is necessary to improve intraoperative and virtual measurement correlation. We found 0.85 for CT- and 0.78 for MRI-based volumetry the most appropriate conversion factors.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2009.09.005Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2009.09.005;
- PII
- S0720-048X(09)00524-5;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 75
- Journal Issue
- 1
- Journal Page Range
- p. e107-e111
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42017900
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- COMPARATIVE EVALUATIONS; COMPUTER CODES; COMPUTERIZED TOMOGRAPHY; LIVER; NMR IMAGING; SURGERY
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; EVALUATION; GLANDS; MEDICINE; ORGANS; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.