Published August 2000 | Version v1
Journal article

Radon dose and aerosols

  • 1. Osijek Univ. (Croatia). Faculty of Education

Description

The equilibrium factor value (F) was measured in the NRPB radon chamber and the corresponding track density ratio (r = D/D0) of bare (D) and diffusion (D0) LR-115 nuclear track detectors was determined, as well as the regression equation F(r). Experiments with LR-115 nuclear track detectors and aerosol sources (burning candle and cigarette) were carried out in the Osijek University radon chamber and afterwards an empirical relationship between the equilibrium factor and aerosol concentration was derived. For the purpose of radon dose equivalent assessment, procedures for determining the unattached fraction of radon progeny were introduced using two nuclear track detectors. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
245
Journal Issue
2
Journal Page Range
p. 371-374
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
16 refs.