Preliminary validation of a Monte Carlo model for IMRT fields
- 1. Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), Melbourne, Victoria, Australia (Australia)
- 2. Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia (Australia)
- 3. School of Chemistry and Physics, University of Adelaide, Adelaide, South Australia, Australia (Australia)
Description
Full text: A Monte Carlo model of an Elekta linac, validated for medium to large (10-30 cm) symmetric fields, has been investigated for small, irregular and asymmetric fields suitable for IMRT treatments. The model has been validated with field segments using radiochromic film in solid water. The modelled positions of the multileaf collimator (MLC) leaves have been validated using EBT film, In the model, electrons with a narrow energy spectrum are incident on the target and all components of the linac head are included. The MLC is modelled using the EGSnrc MLCE component module. For the validation, a number of single complex IMRT segments with dimensions approximately 1-8 cm were delivered to film in solid water (see Fig, I), The same segments were modelled using EGSnrc by adjusting the MLC leaf positions in the model validated for 10 cm symmetric fields. Dose distributions along the centre of each MLC leaf as determined by both methods were compared. A picket fence test was also performed to confirm the MLC leaf positions. 95% of the points in the modelled dose distribution along the leaf axis agree with the film measurement to within 1%/1 mm for dose difference and distance to agreement. Areas of most deviation occur in the penumbra region. A system has been developed to calculate the MLC leaf positions in the model for any planned field size.
Additional details
Publishing Information
- Publisher
- Australasian College of Physical Scientists and Engineers in Medicine
- Imprint Place
- Darwin (Australia)
- Imprint Title
- Abstract EPSM-ABEC 2011 Conference
- Imprint Pagination
- 79 p.
- Journal Page Range
- p. 602
Conference
- Title
- The Engineering and Physical Sciences in Medicine and the Australian Biomedical Engineering Conference
- Acronym
- EPSM-ABEC 2011
- Dates
- 14-18 Aug 2011
- Place
- Darwin (Australia)
INIS
- Country of Publication
- Australia
- Country of Input or Organization
- Australia
- INIS RN
- 44026382
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CALCULATION METHODS; COLLIMATORS; CT-GUIDED RADIOTHERAPY; MONTE CARLO METHOD; NUCLEAR MEDICINE; RADIATION DOSE DISTRIBUTIONS; RADIOLOGY; RADIOTHERAPY; SPATIAL DOSE DISTRIBUTIONS
- Descriptors DEC
- CALCULATION METHODS; MEDICINE; NUCLEAR MEDICINE; RADIATION DOSE DISTRIBUTIONS; RADIOLOGY; RADIOTHERAPY; THERAPY