Published August 2017 | Version v1
Journal article

Improvement of AMS calibration equipment in radiation protection area

  • 1. Taishan Nuclear Power Joint Venture Co. Ltd., Taishan (China)

Description

There is a strong radioactive source in the EPR's AMS calibration equipment, but the shielding design has a defect, which will increase the irradiation dose and unplanned irradiation risk. The equipment was redesigned to decrease the dose and the risk. Besides, the effect evaluation was implemented based on MCNP software calculation. Finally, the optimization of radiation protection is realized. The design theory and the calculation method are introduced in the paper. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
38
Journal Issue
4
Journal Page Range
p. 47-50
ISSN
0258-0926

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
52062095
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Descriptors DEI
CALCULATION METHODS; CALIBRATION; COMPUTER CODES; DEFECTS; DESIGN; EQUIPMENT; EVALUATION; HAZARDS; IRRADIATION; OPTIMIZATION; RADIATION DOSES; RADIATION PROTECTION; RADIATION SOURCES; SHIELDING
Descriptors DEC
DOSES

Optional Information

Notes
3 figs., 4 tabs., 3 refs.