Published November 7, 2005 | Version v1
Journal article

Anisotropic multi-scale fluid registration: evaluation in magnetic resonance breast imaging

  • 1. Centre for Medical Image Computing (CMIC), University College London, London, WC1E 6BT (United Kingdom)

Description

Registration using models of compressible viscous fluids has not found the general application of some other techniques (e.g., free-form-deformation (FFD)) despite its ability to model large diffeomorphic deformations. We report on a multi-resolution fluid registration algorithm which improves on previous work by (a) directly solving the Navier-Stokes equation at the resolution of the images (b) accommodating image sampling anisotropy using semi-coarsening and implicit smoothing in a full multi-grid (FMG) solver and (c) exploiting the inherent multi-resolution nature of FMG to implement a multi-scale approach. Evaluation is on five magnetic resonance (MR) breast images subject to six biomechanical deformation fields over 11 multi-resolution schemes. Quantitative assessment is by tissue overlaps and target registration errors and by registering using the known correspondences rather than image features to validate the fluid model. Context is given by comparison with a validated FFD algorithm and by application to images of volunteers subjected to large applied deformation. The results show that fluid registration of 3D breast MR images to sub-voxel accuracy is possible in minutes on a 1.6 GHz Linux-based Athlon processor with coarse solutions obtainable in a few tens of seconds. Accuracy and computation time are comparable to FFD techniques validated for this application

Availability note (English)

Available online at http://stacks.iop.org/0031-9155/50/5153/pmb5_21_014.pdf or at the Web site for the journal Physics in Medicine and Biology (ISSN 1361-6560) http://www.iop.org/

Additional details

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
50
Journal Issue
21
Journal Page Range
p. 5153-5174
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
37048611
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; ALGORITHMS; ANISOTROPY; GHZ RANGE 01-100; IMAGES; MAMMARY GLANDS; NAVIER-STOKES EQUATIONS; NMR IMAGING; SPATIAL RESOLUTION
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DIFFERENTIAL EQUATIONS; EQUATIONS; FREQUENCY RANGE; GHZ RANGE; GLANDS; MATHEMATICAL LOGIC; ORGANS; PARTIAL DIFFERENTIAL EQUATIONS; RESOLUTION