Published February 2008 | Version v1
Journal article

Flat-Panel CT as a new perinterventional imaging modality in aortic stentgraft procedures. Work in progress

  • 1. Inst. fuer diagnostische und interventionelle Radiologie, LKH Klagenfurt (Austria)

Description

Purpose: to evaluate the value of flat-panel CT (FP-CT) as a new perinterventional imaging modality in aortic stentgraft procedures. Materials and methods: FP-CT was performed in 21 patients (19 males, mean age 77, range 54 to 90) from June 2005 to February 2007 immediately after endovascular treatment of thoracic and abdominal aortic aneurysms on the angiographic table. Nine thoracic aortic aneurysms were treated with Zenith trademark -endoprosthesis. Nine of twelve abdominal aortic aneurysms were treated with Zenith trademark -Endoprosthesis and three with an Excluder trademark -Endoprosthesis. Images were acquired with a rotating C-arm and the following parameters: during an acquisition time of 20 seconds and at a rotation of 217 degrees, 538 projections were acquired. Contrast agent was administered in 14 patients. Images were displayed in MIP, MPR and VRT mode. Results: in all patients the stentgraft was shown exactly and the alignment of the prosthesis along the landing zones was well displayed. The aneurismal sack was well shown in all patients. 1 x an endoleak II was detected, 1 x an angiographically verified endoleak I was not detected. In one patient distal extension was considered due to suspected short stentgraft at the distal neck. Flat-panel CT showed sufficient neck coverage and no extension was inserted. Due to artifacts of the prosthesis, the platinum markers and the guide wire as well as due to pulsation of the aorta, the resolution of detail decreased and reduced the visualization of the alignment. (orig.)

Additional details

Additional titles

Original title (German)
Flachdetektor-CT als ergaenzende Untersuchung bei der endoluminalen Behandlung von thorakalen und abdominellen Aortenaneurysmen. Erste klinische Erfahrungen

Publishing Information

Journal Title
RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der bildgebenden Verfahren
Journal Volume
180
Journal Issue
2
Journal Page Range
p. 127-133
ISSN
1438-9029
CODEN
RFGNDO

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
39028410
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; DIAGNOSIS; GRAFTS; IMAGES; VASCULAR DISEASES
Descriptors DEC
DIAGNOSTIC TECHNIQUES; DISEASES; TOMOGRAPHY; TRANSPLANTS