Lump correction and identification in the combined thermal/epithermal neutron (CTEN) method

Description

The authors present a model for self shielding in lumps of fissile material in active-neutron assays. The model combines the formula for self-attenuation of gamma-ray in lumpy sources with the multi-group analysis techniques used in neutron transport calculations. Models for thin foils and for spheres are examined in terms of error multiplication in determining lump corrections and the basic accuracy of the model

Availability note (English)

Available from INIS in electronic form; ALSO AVAILABLE FROM OSTI AS DE99002307; NTIS; INIS; US GOVT. PRINTING OFFICE DEP.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
13 p.
Report number
LA-UR--98-3251

Conference

Title
39. Institute of Nuclear Materials Management (INMM) annual meeting
Dates
26-30 Jul 1998
Place
Naples, FL (United States)