Published September 1989 | Version v1
Journal article

Ion chromatographic determination of anionic impurities in the secondary water system of nuclear power stations

Creators

  • 1. Zentralinstitut fuer Kernforschung, Rossendorf (German Democratic Republic)

Description

The nonsuppressed anion chromatography with indirect UV-detection is demonstrated as a suitable method for the trace analysis in the secondary water system of nuclear power stations. Coated silica based reversed phase material was used as ion exchanger. This material has a high chromatograhic efficiency and selectivity. The used hardware allows the determination of chloride and sulfate with a detection limit of 0.8 ppb and a relative standard deviation of 20%. (author)

Additional details

Publishing Information

Journal Title
Isotopenpraxis
Journal Volume
25
Journal Issue
9
Series
Isotopenpraxis.
Journal Page Range
415-419
ISSN
0021-1915
CODEN