Published October 1, 1986
| Version v1
Journal article
Self-shielding correction for the resonance activation detectors Na, Mn and Co
Creators
- 1. Zentralinstitut fuer Kernforschung, Rossendorf bei Dresden (German Democratic Republic)
Description
Self-shielding correction factors of infinite slabs have been calculated for the lowest single resonances of Co and Na as well as for the lower two resonances of Mn. (orig.)
Additional details
Publishing Information
- Journal Title
- Nucl. Instrum. Methods Phys. Res., Sect. A
- Journal Volume
- 251
- Journal Issue
- 1
- Series
- Nucl. Instrum. Methods Phys. Res., Sect. A.
- Journal Page Range
- 193-195
- ISSN
- 0168-9002
- CODEN
- NIMAE
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 18006290
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACTIVATION DETECTORS; COBALT 59 TARGET; COBALT 60; CORRECTIONS; MANGANESE 55 TARGET; MANGANESE 56; NEUTRON REACTIONS; RESONANCE; SELF-SHIELDING; SODIUM 23 TARGET; SODIUM 24
- Descriptors DEC
- BARYON REACTIONS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; COBALT ISOTOPES; HADRON REACTIONS; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTO; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LIGHT NUCLEI; MANGANESE ISOTOPES; MEASURING INSTRUMENTS; MILLISEC LIVING RADIOISOTOPES; MINUTES LIVING RADIOISOTOPES; NEUTRON DETECTORS; NUCLEAR REACTIONS; NUCLEI; NUCLEON REACTIONS; ODD-ODD NUCLEI; RADIATION DETECTORS; RADIOISOTOPES; SODIUM ISOTOPES; TARGETS; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- Letter-to-the-editor.