Published July 2012 | Version v1
Journal article

MR neurography of the median nerve at 3.0 T: Optimization of diffusion tensor imaging and fiber tractography

  • 1. Department of Radiology, University Hospital Zurich, Ramistrasse 100, CH 8091 Zurich (Switzerland)
  • 2. Musculoskeletal Radiology, Johns Hopkins University Hospital, Baltimore, MD (United States)
  • 3. Institute for Biomedical Engineering, ETH and University of Zurich (Switzerland)

Description

Objectives: The purpose of this study was to systematically assess the optimal b-value and reconstruction parameters for DTI and fiber tractography of the median nerve at 3.0 T. Methods: Local ethical board approved study with 45 healthy volunteers (15 men, 30 women; mean age, 41 ± 3.4 years) who underwent DTI of the right wrist at 3.0 T. A single-shot echo-planar-imaging sequence (TR/TE 10123/40 ms) was acquired at four different b-values (800, 1000, 1200, and 1400 s/mm2). Two independent readers performed post processing and fiber-tractography. Fractional anisotropy (FA) maps were calculated. Fiber tracts of the median nerve were generated using four different algorithms containing different FA thresholds and different angulation tolerances. Data were evaluated quantitatively and qualitatively. Results: Tracking algorithms using a minimum FA threshold of 0.2 and a maximum angulation of 10° were significantly better than other algorithms. Fiber tractography generated significantly longer fibers in DTI acquisitions with higher b-values (1200 and 1400 s/mm2 versus 800 s/mm2; p < 0.001). The overall quality of fiber tractography was best at a b-value of 1200 s/mm2 (p < 0.001). Conclusions: In conclusion, our results indicate use of b-values between 1000 and 1400 s/mm2 for DTI of the median nerve at 3.0 T. Optimal reconstruction parameters for fiber tractography should encompass a minimum FA threshold of 0.2 and a maximum angulation tolerance of 10.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2012.03.017

Additional details

Identifiers

DOI
10.1016/j.ejrad.2012.03.017;
PII
S0720-048X(12)00114-3;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
81
Journal Issue
7
Journal Page Range
p. e775-e782
ISSN
0720-048X
CODEN
EJRADR

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
43078770
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ALGORITHMS; ANISOTROPY; FIBERS; NERVOUS SYSTEM; NMR IMAGING
Descriptors DEC
DIAGNOSTIC TECHNIQUES; MATHEMATICAL LOGIC

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.