Published 1995 | Version v1
Book

Fluidelastic instability analysis of steam generator U-tubes at antivibration bar-inactive modes

  • 1. Korea Inst. of Nuclear Safety, Taejon (Korea, Republic of)

Description

This paper presents the results of thermal-hydraulic and fluidelastic U-tube instability analyses performed for the vertical type pressurized water reactor (PWR) steam generator model being employed at Kori units 2, 3 and 4, and Yonggwang units 1 and 2 in Korea. The thermal-hydraulic analysis for providing the detailed three-dimensional two-phase flow field in the secondary side of the steam generator was accomplished using the ATHOS3 steam generator thermal-hydraulic analysis code. The UTVA2 code designed for calculating both the free vibration responses and fluidelastic stability ratio of a specific U-tube under consideration was used to assess the potential for fluidelastic instability of the steam generator U-tubes at various conditions of antivibration bar (AVB)-inactive modes. The results of the fluidelastic instability analysis were discussed in comparison with those obtained for the steam generator U-tubes at AVB-active mode

Additional details

Publishing Information

Publisher
American Society of Mechanical Engineers.
Imprint Place
New York, NY (United States)
ISBN
0-7918-1342-8
Imprint Title
Transient thermal hydraulics, heat transfer, and coupled vessel and piping responses. PVP-Volume 311
Imprint Pagination
116 p.
Journal Page Range
p. 87-95.

Conference

Title
Joint ASME/JSME pressure vessels and piping conference.
Dates
23-27 Jul 1995.
Place
Honolulu, HI (United States).

Optional Information

Secondary number(s)
CONF-950740--.