Published January 1982 | Version v1
Journal article

System for coordinated time measurement

  • 1. AN SSSR, Moscow. Inst. Yadernykh Issledovanij

Description

A system for timing experimental data obtained at the physical installation for detecting neutrino fluxes from collapsing stars by means of the scale of the Soviet Coordinated Time (UTC(SU)) on the scales of the Universal Coordinated Time (UTC) is described. The timing is performed using the Soviet and radiochannels. The error of timing on the UTC(SU) scale is not worse than +-1.1 μs. The relative daily instability of a time keeper a'mouts to 1.7x10-9. The time measurement error without a nonius scale is 1 ms, with a nonius scale it is equal to 10 μs

Additional details

Additional titles

Original title (Russian)
Sistema izmereniya koordinirovannogo vremeni

Publishing Information

Journal Title
Prib. Tekh. Ehksp.
Journal Issue
no.1
Series
Prib. Tekh. Ehksp.
ISSN
0032-8162

Optional Information

Notes
For English translation see the journal Instruments and Experimental Techniques (USA).