Analyses of selected initiation events based on an experiment on the LOBI facility. Rev. 0

Description

The report is a summary of a post-test calculation of a steam line break on the LOBI experimental facility at a zero hot power. The ATHLET Mod 2.1 Cycle A best-estimate computer code was used for the analysis. (author)