Published August 1, 1976
| Version v1
Journal article
A surface-ionization ion source designed for in-beam operation with the BEMS-2 isotope separator
- 1. Joint Inst. for Nuclear Research, Dubna (USSR)
Description
A surface-ionization ion source designed to operate in combination with the BEMS-2 isotope separator in a heavy ion beam is described. The ion source is adjusted for the separation of rare-earth elements. The separation efficiency for 150Dy is determined to be equal to about 20% at an ionizer temperature of 2600 K. The hold-up times for praseodymium, promethium and dysprosium in the ion source range from 5 to 10 s at ionizer temperatures of 2500-2700 K. (Auth.)
Additional details
Identifiers
Publishing Information
- Journal Title
- Nuclear Instruments and Methods
- Journal Volume
- 136
- Journal Issue
- 3
- Series
- Nucl. Instrum. Methods.
- Journal Page Range
- 433-435
- ISSN
- 0029-554X
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 7278928
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- EFFICIENCY; HEAVY IONS; ION BEAMS; ION SOURCES; ISOTOPE SEPARATION; RARE EARTHS; SPECIFICATIONS; SURFACE IONIZATION; VERY HIGH TEMPERATURE
- Descriptors DEC
- BEAMS; CHARGED PARTICLES; ELEMENTS; IONIZATION; IONS; METALS; SEPARATION PROCESSES
Optional Information
- Notes
- Updated automatically by Metadata and Full-Text Enrichment Agent