Treatment of Non-Small Cell Lung Cancer Patients With Proton Beam-Based Stereotactic Body Radiotherapy: Dosimetric Comparison With Photon Plans Highlights Importance of Range Uncertainty

  • 1. Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, MA (United States)
  • 2. Harvard Radiation Oncology Program, Harvard Medical School, Boston, MA (United States)

Description

Purpose: Proton beam radiotherapy has been proposed for use in stereotactic body radiotherapy (SBRT) for early-stage non–small-cell lung cancer. In the present study, we sought to analyze how the range uncertainties for protons might affect its therapeutic utility for SBRT. Methods and Materials: Ten patients with early-stage non–small-cell lung cancer received SBRT with two to three proton beams. The patients underwent repeat planning for photon SBRT, and the dose distributions to the normal and tumor tissues were compared with the proton plans. The dosimetric comparisons were performed within an operational definition of high- and low-dose regions representing volumes receiving >50% and <50% of the prescription dose, respectively. Results: In high-dose regions, the average volume receiving ≥95% of the prescription dose was larger for proton than for photon SBRT (i.e., 46.5 cm3 vs. 33.5 cm3; p = .009, respectively). The corresponding conformity indexes were 2.46 and 1.56. For tumors in close proximity to the chest wall, the chest wall volume receiving ≥30 Gy was 7 cm3 larger for protons than for photons (p = .06). In low-dose regions, the lung volume receiving ≥5 Gy and maximum esophagus dose were smaller for protons than for photons (p = .019 and p < .001, respectively). Conclusions: Protons generate larger high-dose regions than photons because of range uncertainties. This can result in nearby healthy organs (e.g., chest wall) receiving close to the prescription dose, at least when two to three beams are used, such as in our study. Therefore, future research should explore the benefit of using more than three beams to reduce the dose to nearby organs. Additionally, clinical subgroups should be identified that will benefit from proton SBRT.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2011.05.062

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2011.05.062;
PII
S0360-3016(11)02812-4;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
83
Journal Issue
1
Journal Page Range
p. 354-361
ISSN
0360-3016
CODEN
IOBPD3

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.