Research for obtaining a detection system with high spatial and temporal resolution for a tomograph with positron emission (PET-Tomography)
- 1. Horia Hulubei National Institute for Physics and Nuclear Engineering, PO Box MG-6, RO-76900 Bucharest - Magurele (Romania)
Description
This report describes a new type of detector for a tomograph system with positron emission. The detector has a new design with detection characteristics better than other detectors used currently in tomographic systems. We have in view the detectors like NaI(Tl), CsI(Tl), BGO and others. The new detector is based on discharge in gases and the interaction of gamma radiation - generated in the annihilation processes of positrons - with the mixture of gases within detector. The main novelty is the structure of electrodes with central readout microstrip plate. This structure is composed from two identical chambers. Each of these chambers have two glass resistive electrodes and one metallic electrode (cathode). One of the glass electrodes is separated from the metallic electrode while the other one is in contact with the central readout microstrip plate. In this way to gaps of 0.3 mm are generated. The gas mixture flows between these gaps. The electric charges generated in this gas are collected on the strips under the influence of the electric field applied between cathode and the anode of the detector.The arrangement of electrodes is shown. The structure of electrodes is mounted into a metallic box of special construction which allows the gas to flow through the detector and collects the electric charges generated in the detector. At present the detector is in the stage of a laboratory model and the tests carried out led to the following detection parameters: detection efficiency, 95%; spatial resolution, 3 mm; time resolution, 82 ps. The measurements were performed in coincidence using two similar detectors and the source of positrons was located between detectors. In the next stage of research will be defined the final constructive solution of the experimental model, built and tested for this positron source. The mixture of gases used for tests contained 85%C2H2F4 + 10%SF6 + 5%C4H10 (isobutane). (authors)
Availability note (English)
Available from author(s) or Institute of Atomic Physics, PO Box MG-3, RO-76900 Bucharest - Magurele (RO)Additional details
Publishing Information
- Publisher
- CONPHYS
- Imprint Place
- Bucharest (Romania)
- ISBN
- 973-8488-09-5
- Imprint Title
- National Plan for Research - Development and Innovation, CERES Programme. Annual Scientific Session
- Imprint Pagination
- 308 p.
- Journal Page Range
- p. 173-174
Conference
- Title
- National Plan for Research - Development and Innovation, CERES Programme. Annual Scientific Session
- Dates
- 2-3 Dec 2002
- Place
- Bucharest (Romania)
INIS
- Country of Publication
- Romania
- Country of Input or Organization
- Romania
- INIS RN
- 34071930
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Non-conventional Literature, Conference
- Descriptors DEI
- 2-METHYLPROPANE; ANNIHILATION; EFFICIENCY; ELECTRODES; EMISSION COMPUTED TOMOGRAPHY; GAMMA DETECTION; POSITRON COMPUTED TOMOGRAPHY; SPATIAL RESOLUTION; SULFUR FLUORIDES; TIME RESOLUTION
- Descriptors DEC
- ALKANES; COMPUTERIZED TOMOGRAPHY; DETECTION; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; FLUORIDES; FLUORINE COMPOUNDS; HALIDES; HALOGEN COMPOUNDS; HYDROCARBONS; INTERACTIONS; ORGANIC COMPOUNDS; PARTICLE INTERACTIONS; RADIATION DETECTION; RESOLUTION; SULFUR COMPOUNDS; TIMING PROPERTIES; TOMOGRAPHY
Optional Information
- Contract/Grant/Project number
- Contract CERES 69/2001
- Notes
- 2 refs., 1 fig.