Published 2001 | Version v1
Journal article

Gamma-ray tracking - A new detector concept for nuclear spectroscopy

Creators

  • 1. TMR Network, Forschungszentrum Juelich, IKP, 52425 Juelich (Germany)

Description

In the framework of an European collaboration the nest generation of large efficiency, high resolution spectrometers for nuclear spectroscopy is under development. The new spectrometers are large volume, segmented Ge-detectors featuring 3D position sensitivity in order to allow Gamma-Ray Tracking. That is, knowing the interaction positions and the energies released at each interaction, the track each gamma-ray follows during its scattering process inside the detector volume can be reconstructed on basis of the Compton-scattering formula. The resulting high add-back efficiency an effective granularity significantly improves peak-to-total ratio, efficiency, and Doppler-broadening of the spectrometer. In this contribution the states of the project concerning detector design and development of digital signal processing techniques to achieve an optimal 3D position sensitivity is presented. (authors)

Additional details

Publishing Information

Journal Title
Romanian Journal of Physics
Journal Volume
46
Journal Issue
1-2
Journal Page Range
p. 79-88
ISSN
1221-146X

Optional Information

Notes
11 refs., 1 tab., 7 figs.