Published July 2000 | Version v1
Journal article

Monte Carlo calculation of dose distribution from '188Re/186Re liquid filled balloon for intracoronary brachytherapy

  • 1. Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai (India)

Description

In India, 188Re/186Re liquid filled balloons are currently under clinical trials, but no accurate dosimetric data is available. The results of the calculation of dose distribution in water using Electron Gamma Shower (EGS-4) code system is given

Additional details

Publishing Information

Journal Title
Journal of Medical Physics
Journal Volume
25
Journal Issue
3
Journal Page Range
p. 136-137
CODEN
JMPHFE

Conference

Title
21. annual conference on medical physics
Dates
9-11 Nov 2000
Place
Bangalore (India)

Optional Information

Notes
4 refs., 2 tabs.