Published August 1999 | Version v1
Journal article

Cost-effectiveness analysis on the results of screening of lung cancer using helical CT conducted by the anti-lung cancer association (ALCA)

  • 1. Saitama Inst. of Technology, Okabe (Japan)

Description

To compare Yen/person saved in lung cancer screening using helical CT with Yen/person in the screening using conventional direct chest X-rays conducted under the Anti-lung cancer association program of the Tokyo Health Service Association. A mathematical model for cancer screening was used to estimate net number of person relieved from lung cancer by the screening and net cost required for the screening. Finally cost-effectiveness ratios in terms of Yen/person saved were calculated and compared between the two programs. Several important variables employed in the model were as follows: 5 year survival rate in chest X-ray group was 50%, and the rate in helical CT group was 75%. Cost of screening in the chest X-ray group was 15,000 Yen, and that in the helical CT group was 25,000 Yen. Cost/person screened was 14,470 Yen for chest X-ray and 21,890 Yen for helical CT. Cost/person saved was 267 x 105 Yen in X-ray group and 112 x 105 Yen in CT group. Thus the cost was higher, but cost-effectiveness ratio was better in the CT screening group. Helical CT can be adopted for lung cancer screening in stead of chest X-ray if total cost is affordable. (author)

Additional details

Publishing Information

Journal Title
Nippon Kyobu Rinsho
Journal Volume
58
Journal Issue
8
Journal Page Range
p. 591-596
ISSN
0385-3667