Calibration of a proton beam energy monitor
- 1. Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, California 92354 (United States)
Description
Delivery of therapeutic proton beams requires an absolute energy accuracy of ±0.64 to 0.27 MeV for patch fields and a relative energy accuracy of ±0.10 to 0.25 MeV for tailoring the depth dose distribution using the energy stacking technique. Achromatic switchyard tunes, which lead to better stability of the beam incident onto the patient, unfortunately limit the ability of switchyard magnet tesla meters to verify the correct beam energy within the tolerances listed above. A new monitor to measure the proton energy before each pulse is transported through the switchyard has been installed into a proton synchrotron. The purpose of this monitor is to correct and/or inhibit beam delivery when the measured beam energy is outside of the tolerances for treatment. The monitor calculates the beam energy using data from two frequency and eight beam position monitors that measure the revolution frequency of the proton bunches and the effective offset of the orbit from the nominal radius of the synchrotron. The new energy monitor has been calibrated by measuring the range of the beam through water and comparing with published range-energy tables for various energies. A relationship between depth dose curves and range-energy tables was first determined using Monte Carlo simulations of particle transport and energy deposition. To reduce the uncertainties associated with typical scanning water phantoms, a new technique was devised in which the beam energy was scanned while fixed thickness water tanks were sandwiched between two fixed parallel plate ionization chambers. Using a multitude of tank sizes, several energies were tested to determine the nominal accelerator orbit radius. After calibration, the energy reported by the control system matched the energy derived by range measurements to better than 0.72 MeV for all nine energies tested between 40 and 255 MeV with an average difference of -0.33 MeV. A study of different combinations of revolution frequency and radial offsets to test the envelope of algorithm accuracy demonstrated a relative accuracy of ±0.11 MeV for small energy changes between 126 and 250 MeV. These new measurements may serve as a data set for benchmarking range-energy relationships
Additional details
Identifiers
- DOI
- 10.1118/1.2717382;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 34
- Journal Issue
- 6
- Journal Page Range
- p. 1952-1966
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38101712
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ACCURACY; ALGORITHMS; CALIBRATION; COMPUTERIZED SIMULATION; DEPTH DOSE DISTRIBUTIONS; IONIZATION CHAMBERS; MONTE CARLO METHOD; PHANTOMS; PROTON BEAMS; RADIATION MONITORING; RADIOTHERAPY; SYNCHROTRONS
- Descriptors DEC
- ACCELERATORS; BEAMS; CALCULATION METHODS; CYCLIC ACCELERATORS; MATHEMATICAL LOGIC; MEASURING INSTRUMENTS; MEDICINE; MOCKUP; MONITORING; NUCLEAR MEDICINE; NUCLEON BEAMS; PARTICLE BEAMS; RADIATION DETECTORS; RADIATION DOSE DISTRIBUTIONS; RADIOLOGY; SIMULATION; SPATIAL DOSE DISTRIBUTIONS; STRUCTURAL MODELS; THERAPY
Optional Information
- Notes
- (c) 2007 American Association of Physicists in Medicine