Published February 1991
| Version v1
Journal article
Comments on the assessment of α-efficiency K value
- 1. Institute of Marine Geology, Ministry of Geoloyg and Mineral Resource (China)
- 2. National Inst. of Metrology (China)
Description
It was found that K value can be reflected by the ratio of natural ESR signal intensity I0 to the maximum ESR signal intensity Imax at dose saturation. An equation of assessment of k value, derived from several samples of aragonitic corals compared with U-series dating, was obtained. The precision of ESR dating can be improved by using the equation
Additional details
Publishing Information
- Journal Title
- Nuclear Techniques
- Journal Volume
- 14
- Journal Issue
- 2
- Series
- Nucl. Tech.
- Journal Page Range
- 77-78
- ISSN
- 0253-3219
- CODEN
- NUTED
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 23010547
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- ACCURACY; AGE ESTIMATION; ALPHA DETECTION; CORALS; EFFICIENCY; ELECTRON SPIN RESONANCE; EQUATIONS
- Descriptors DEC
- ANIMALS; CHARGED PARTICLE DETECTION; CNIDARIA; COELENTERATA; DETECTION; INVERTEBRATES; MAGNETIC RESONANCE; RADIATION DETECTION; RESONANCE