Published December 2013
| Version v1
Journal article
Optimization research on CEFR whole-range reactor period protection function
- 1. China Institute of Atomic Energy, Beijing (China)
- 2. Nuclear and Radiation Safety Center, Ministry of Environmental Protection, Beijing (China)
Description
To solve the problem of false short period alarm of China Experimental Fast Reactor (CEFR) neutron instrumentation system (NIS), optimization research on the CEFR whole-range reactor period protection function was done through theoretical calculation and analysis according to the characteristics of CEFR NIS. In addition, the NIS was simulated using Matlab/Simulink software, and the results show that the optimized scheme is accurate and feasible. (authors)