Pressure Drop Test of Hybrid Mixing Vane Spacer Grid
Description
The pressure loss test has been accomplished in the test section containing 5x5 rod bundle with a length of 2 m including 3 spacer grids. The test has been performed for the 5 kinds of spacer grids to compare the pressure loss characteristics: 1. Plain spacer grid which has the same body of the Hybrid but without vane (Plain), 2. Hybrid Vane spacer grid (Hybrid), 3. Hybrid-SC spacer grid which is constructed with coined, chamfered strip and is fabricated by spot welding, 4. Hybrid-LC spacer grid which is constructed with coined, chamfered strip and is fabricated by line welding along intersection line, 5. Westinghouse spacer grid with split vane (Plus-7). The pressure loss coefficient of the Plain, Hybrid, Hybrid-SC, Hybrid-LC, and Plus-7 spacer grid is 0.93, 1.15, 1.02, 1.04, and 1.08, respectively
Availability note (English)
Available from INIS in electronic form; Also available from KAERIFiles
39084666.pdf
Files
(2.8 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:f52f88226377fd0d862b65598638a0a5
|
2.8 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 91 p.
- Report number
- KAERI/TR--3441/2007
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 39084666
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- FUEL ELEMENT CLUSTERS; MIXING; PRESSURE DROP; SPACERS; VANES; WELDING
- Descriptors DEC
- FABRICATION; FUEL ASSEMBLIES; JOINING
Optional Information
- Notes
- 28 figs, 5 tabs