Pressure Drop Test of Hybrid Mixing Vane Spacer Grid

Description

The pressure loss test has been accomplished in the test section containing 5x5 rod bundle with a length of 2 m including 3 spacer grids. The test has been performed for the 5 kinds of spacer grids to compare the pressure loss characteristics: 1. Plain spacer grid which has the same body of the Hybrid but without vane (Plain), 2. Hybrid Vane spacer grid (Hybrid), 3. Hybrid-SC spacer grid which is constructed with coined, chamfered strip and is fabricated by spot welding, 4. Hybrid-LC spacer grid which is constructed with coined, chamfered strip and is fabricated by line welding along intersection line, 5. Westinghouse spacer grid with split vane (Plus-7). The pressure loss coefficient of the Plain, Hybrid, Hybrid-SC, Hybrid-LC, and Plus-7 spacer grid is 0.93, 1.15, 1.02, 1.04, and 1.08, respectively

Availability note (English)

Available from INIS in electronic form; Also available from KAERI

Files

39084666.pdf

Files (2.8 MB)

Name Size Download all
md5:f52f88226377fd0d862b65598638a0a5
2.8 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
91 p.
Report number
KAERI/TR--3441/2007

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
39084666
Subject category
S42: ENGINEERING;
Descriptors DEI
FUEL ELEMENT CLUSTERS; MIXING; PRESSURE DROP; SPACERS; VANES; WELDING
Descriptors DEC
FABRICATION; FUEL ASSEMBLIES; JOINING

Optional Information

Notes
28 figs, 5 tabs