Use of energy deposition spectrometer Liulin for individual monitoring of aircrew
- 1. Nuclear Physics Inst., Dept. of Radiation Dosimetry, Czech Academy of Sciences, Prague (Czech Republic)
- 2. National Inst. of Radiological Sciences, Fundamental Technology Center, RMR Section, Chiba (Japan)
- 3. Solar-Terrestrial Influences Inst. (Bulgaria)n Academy of Sciences, Sofia, Bulgaria
Description
Silicon energy deposition spectrometer Liulin was primarily developed for cosmic radiation monitoring onboard spacecrafts. Nowadays, Liulin type detectors are also used to characterise radiation field on board aircraft, at alpine observatories and behind the shielding of heavy ion accelerators. In this work, experiments and calibrations performed in these radiation fields are presented and the method developed for calculation of ambient dose equivalent H*(10) on board aircraft is described. Since 2001, a simple method employing the energy deposition spectra had been used to determine H*(10) on board aircraft but, in 2004, it became clear that the resulting values were strongly biased at locations close to Earth's equator. An improved method for the determination of H*(10) on board aircraft using the Liulin detector was developed. It took into account the composition of the radiation field via the ratio of absorbed doses Dlow and Dneut reflecting the contributions from low-LET particles and neutrons, respectively. It resulted in much better agreement with the EPCARD computer code for all aircraft locations; relative differences were within 11 % for low-LET and 20 % for neutron components of H*(10). (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncq505Additional details
Identifiers
- DOI
- 10.1093/rpd/ncq505;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 144
- Journal Issue
- 1-4
- Journal Page Range
- p. 611-614
- ISSN
- 0144-8420
Conference
- Title
- European conference on individual monitoring of ionising radiation
- Acronym
- IM2010
- Dates
- 8-12 Mar 2010
- Place
- Athens (Greece)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 43077559
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AIRCRAFT; COSMIC RADIATION; DOSE EQUIVALENTS; HEAVY ION ACCELERATORS; NEUTRONS; RADIATION MONITORING; RADIATION PROTECTION; SILICON; STATISTICAL MODELS
- Descriptors DEC
- ACCELERATORS; BARYONS; ELEMENTARY PARTICLES; ELEMENTS; FERMIONS; HADRONS; IONIZING RADIATIONS; MATHEMATICAL MODELS; MONITORING; NUCLEONS; RADIATIONS; SEMIMETALS
Optional Information
- Notes
- 11 refs