Ability of chest X-ray to detect faint shadows documented as ground-glass attenuation in images of computed tomography: A comparison between flat-panel detector radiography and film-screen radiography

  • 1. Department of Radiology, Shiga University of Medical Science, Seta Tsukinowa-cho, Otsu, Shiga 520-2121 (Japan)
  • 2. Department of Radiological Technology, Nagoya University School of Health Sciences, 1-20 Daikominami 1-chome, Higashi-ku, Nagoya 461-8673 (Japan)

Description

Purpose: To compare flat-panel detector (FPD) radiography and film-screen (FS) radiography in detectability of faint shadows documented as ground-glass attenuation (GGA) areas in images of computed tomography (CT). Materials and methods: Study population was comprised of 50 patients who underwent FS and another 50 patients who underwent FPD. Standard of reference (SOR) was determined on the basis of area of GGA in all cross-sections of CT, in terms of GGA extent and presence or absence of GGA in each trisected lung fields (GGA distribution). Eight radiologists assessed the GGA extent with the 5-grade scale and the GGA distribution. Inter-observer variances of the GGA extents and distributions, degree of divergences and correspondence in the GGA extent and distributions with SOR, were compared between the FS and FPD by the jackknife method and Fisher's exact test. Results: Inter-observer variance in the GGA extent and distribution were slightly larger in the FS than in the FPD. The GGA extent scale corresponded with SOR in the FS statistically significantly better (p = 0.001), as the correct ratio was 0.428 in the FS and 0.310 in the FPD. Divergence in the GGA extent scale with SOR was smaller in the FS, as average kappa pseudo-value of Kendall's rank correlation coefficient was 0.474 in the FS and 0.433 in the FPD. Conclusion: These results indicate that some lesions of GGA documented in CT may not be reflected and are difficult to be detected in chest X-ray radiographs with the FPD.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2009.04.057

Additional details

Identifiers

DOI
10.1016/j.ejrad.2009.04.057;
PII
S0720-048X(09)00263-0;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
75
Journal Issue
3
Journal Page Range
p. 384-390
ISSN
0720-048X
CODEN
EJRADR

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42017969
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CHEST; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; IMAGES; LUNGS; X RADIATION
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; ELECTROMAGNETIC RADIATION; EVALUATION; IONIZING RADIATIONS; ORGANS; RADIATIONS; RESPIRATORY SYSTEM; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.