Description

This paper describes the design, construction, and operation of devices used to rapidly measure the mechanical and magnetic properties of some 950 Alternate gradient magnets used in the arc system of the Stanford Linear Collider. The problems of dealing with the measurement of the transverse dimensions to within minute (0.0001 in) resolution of objects that are 8 ft long are discussed. Early results from the production runs of these magnets are presented

Additional details

Publishing Information

Imprint Title
IEEE Transactions on Nuclear Science, Volume NS-32, No. 5. 1985 Particle accelerator conference. Accelerator engineering and technology
Journal Page Range
p. 3660-3662.
Report number
DOE/ER/40238--1

Conference

Title
Particle accelerator conference.
Dates
13-16 May 1985.
Place
Vancouver (Canada).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
18023644
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
BEAM BENDING MAGNETS; DIMENSIONS; MAGNETIC FIELDS; MEASURING METHODS; MECHANICAL PROPERTIES; RESOLUTION; STANFORD LINEAR COLLIDER
Descriptors DEC
ACCELERATORS; EQUIPMENT; LINEAR ACCELERATORS; MAGNETS