Published 2012 | Version v1
Miscellaneous

The effect of flow-accelerated corrosion with high-temperature sodium hydroxide on tube target-wastage caused in steam generator of sodium-cooled fast reactor

  • 1. Japan Atomic Energy Agency, Oarai, Ibaraki (Japan)

Description

Wastage phenomena on adjacent tubes (target-wastage) arise from water/steam leak in steam generators of sodium-cooled fast reactors. Target-wastage is likely to be caused by liquid droplet impingement erosion and flow-accelerated corrosion in an environment marked by high-temperature and high-alkali (reaction jet) due to sodium-water reaction. The static and flow-accelerated corrosion experiments have been carried out as a part of phenomena clarification experiments for target-wastage by using tube material under high-temperature sodium-hydroxide and sodium monoxide conditions which are mainly generated by sodium-water reaction. The authors evaluated the dependence of liquid/tube material temperature and liquid impingement velocity upon the flow-accelerated corrosion rate on the tube in this report. (author)

Part of:
The 17th national symposium on power and energy systems (SPES 2012)

Additional details

Publishing Information

Imprint Title
The 17th national symposium on power and energy systems (SPES 2012)
Imprint Pagination
464 p.
Journal Page Range
p. 309-310

Conference

Title
17. national symposium on power and energy systems
Acronym
SPES 2012
Dates
21-22 Jun 2012
Place
Fukuoka (Japan)

Optional Information

Notes
3 refs., 4 figs.