Published April 1999 | Version v1
Journal article

An improved approach to reduce partial volume errors in brain SPET

  • 1. The Queen Elizabeth Hospital, Adelaide, SA (Australia). Department of Nuclear Medicine
  • 2. QUT, Brisbane, QLD (Australia). Centre for Medical and Health Physics
  • 3. Westmead Hospital, Westmead, Sydney, NSW (Australia). Department of Medical Physics

Description

Full text: Limitations in SPET resolution give rise to significant partial volume error (PVE) in small brain structures We have investigated a previously published method (Muller-Gartner et al., J Cereb Blood Flow Metab 1992;16: 650-658) to correct PVE in grey matter using MRI. An MRI is registered and segmented to obtain a grey matter tissue volume which is then smoothed to obtain resolution matched to the corresponding SPET. By dividing the original SPET with this correction map, structures can be corrected for PVE on a pixel-by-pixel basis. Since this approach is limited by space-invariant filtering, modification was made by estimating projections for the segmented MRI and reconstructing these using identical parameters to SPET. The methods were tested on simulated brain scans, reconstructed with the ordered subsets EM algorithm (8,16, 32, 64 equivalent EM iterations) The new method provided better recovery visually. For 32 EM iterations, recovery coefficients were calculated for grey matter regions. The effects of potential errors in the method were examined. Mean recovery was unchanged with one pixel registration error, the maximum error found in most registration programs. Errors in segmentation > 2 pixels results in loss of accuracy for small structures. The method promises to be useful for reducing PVE in brain SPET

Additional details

Publishing Information

Journal Title
Nuclear Medicine Communications
Journal Volume
20
Journal Issue
4
Journal Page Range
p. 373
ISSN
0143-3636

Conference

Title
30. Annual Scientific Meeting of the Australian and New Zealand Society of Nuclear Medicine
Dates
24-27 Apr 1999
Place
Perth, WA (Australia)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
Australia
INIS RN
32008208
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCURACY; ALGORITHMS; BRAIN; COMPUTERIZED SIMULATION; ERRORS; IMAGE PROCESSING; NMR IMAGING; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; VOLUME
Descriptors DEC
BODY; CENTRAL NERVOUS SYSTEM; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; NERVOUS SYSTEM; ORGANS; PROCESSING; SIMULATION; TOMOGRAPHY

Optional Information

Notes
Abstract only