Published March 2006 | Version v1
Journal article

Study on influence of X-ray baggage scan on ESR dosimetry for SNTS using human tooth enamel

  • 1. Hiroshima Univ., Research Inst. for Radiation Biology and Medicine, Hiroshima, Hiroshima (Japan)
  • 2. Medical Radiological Research Center, Obninsk (RU)

Description

The influence of X-ray baggage scanning on electron spin resonance (ESR) dosimetry studies around the Semipalatinsk Nuclear Test Site (SNTS) has been examined at Incheon Airport in Korea, which is a transfer point of the routes from Kazakhstan to Japan. Utilized dosimeters are Japanese human tooth enamel for ESR and glass dosimeters. The difference between the estimated doses with the X-ray scan and those without it is below the evaluation errors for both ESR and the glass dosimeters. For glass dosimeters, the dose from the X-ray scan is estimated to be lower than the detection limit for the utilized glass dosimeters of ten μGy. This supports the absence of significant difference for the ESR results, which have an error in the other of ten mGy. Since ESR dosimetry for SNTS usually has similar errors, the dose by the X-ray scan in this study is concluded to be negligible in ESR dosimetry using tooth enamel from residents near SNTS. (author)

Additional details

Publishing Information

Journal Title
Journal of Radiation Research
Journal Volume
47
Journal Issue
suppl.A
Journal Page Range
p. A81-A83
ISSN
0449-3060

Conference

Title
3. dosimetry workshop on the Semipalatinsk nuclear test site area
Dates
9-11 Mar 2005
Place
Hiroshima (Japan)

Optional Information

Notes
12 refs., 1 fig., 2 tabs.