Published August 2017 | Version v1
Journal article

Research of test scenario of T2 response time of reactor protection system

  • 1. Fujian Fuqing Nuclear Power Co. Ltd., Fuqing (China)

Description

The composing of the reactor protection system response time was introduced firstly. Considering the complex and difficulty of the test of RPS response time, and high requirement of test theory, two test schemes of all path converge test and all module converge test were introduced. The advantages and disadvantages of two schemes were analyzed. Through three tests during the outage in Fuqing Nuclear Power Plant, the feasibility of the test was proved. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
38
Journal Issue
4
Journal Page Range
p. 116-119
ISSN
0258-0926

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
52062111
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Descriptors DEI
NUCLEAR POWER PLANTS; OUTAGES; REACTOR PROTECTION SYSTEMS
Descriptors DEC
ENGINEERED SAFETY SYSTEMS; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS

Optional Information

Notes
3 figs., 1 tab., 4 refs.