Published August 2017
| Version v1
Journal article
Research of test scenario of T2 response time of reactor protection system
Creators
- 1. Fujian Fuqing Nuclear Power Co. Ltd., Fuqing (China)
Description
The composing of the reactor protection system response time was introduced firstly. Considering the complex and difficulty of the test of RPS response time, and high requirement of test theory, two test schemes of all path converge test and all module converge test were introduced. The advantages and disadvantages of two schemes were analyzed. Through three tests during the outage in Fuqing Nuclear Power Plant, the feasibility of the test was proved. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 38
- Journal Issue
- 4
- Journal Page Range
- p. 116-119
- ISSN
- 0258-0926
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 52062111
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- NUCLEAR POWER PLANTS; OUTAGES; REACTOR PROTECTION SYSTEMS
- Descriptors DEC
- ENGINEERED SAFETY SYSTEMS; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS
Optional Information
- Notes
- 3 figs., 1 tab., 4 refs.