Published 1976 | Version v1
Report Open

Eddy currents: suppression device for automatic testing of finned tubes

Description

Finned tubes present along their length smooth zones that make impossible automatic testing. A device connected on the primary coil allows to eliminate the influence of ends and smooth zones

Availability note (English)

MF available from INIS under the Report Number.

Abstract (French)

Les tubes a ailettes presentent sur leur longueur des zones lisses rendant le controle automatique impossible. Un systeme, branche sur le primaire du capteur permet d'eliminer l'influence des extremites et des zones de transition

Files

8310878.pdf

Files (100.9 kB)

Name Size Download all
md5:660f0a4f4e4e8df003dbcdb57fb41119
100.9 kB Preview Download

Additional details

Additional titles

Original title (French)
Courants de Foucault: systeme d'inhibition pour controle automatique de tubes a ailettes

Publishing Information

Imprint Pagination
4 p.
Report number
FRNC-CONF--169

Conference

Title
8. World conference on nondestructive testing.
Dates
6 Sep 1976.
Place
Cannes, France.

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
8310878
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
EDDY CURRENT TESTING; FINS; TUBES
Descriptors DEC
ELECTROMAGNETIC TESTING; MATERIALS TESTING; NONDESTRUCTIVE TESTING; TESTING