Simulation of computed radiography with imaging plate detectors
Creators
- 1. CEA LIST, CEA Saclay 91191 Gif sur Yvette Cedex (France)
- 2. CEA-LETI, Campus Minatec, F-38054, Grenoble (France)
- 3. EDF R and D, 1 avenue du général de gaulle 92141 Clamart (France)
Description
Computed radiography (CR) using phosphor imaging plate detectors is taking an increasing place in Radiography Testing. CR uses similar equipment as conventional radiography except that the classical X-ray film is replaced by a numerical detector, called image plate (IP), which is made of a photostimulable layer and which is read by a scanning device through photostimulated luminescence. Such digital radiography has already demonstrated important benefits in terms of exposure time, decrease of source energies and thus reduction of radioprotection area besides being a solution without effluents. This paper presents a model for the simulation of radiography with image plate detectors in CIVA together with examples of validation of the model. The study consists in a cross comparison between experimental and simulation results obtained on a step wedge with a classical X-ray tube. Results are proposed in particular with wire Image quality Indicator (IQI) and duplex IQI
Additional details
Identifiers
- DOI
- 10.1063/1.4865050;
Publishing Information
- Journal Title
- AIP Conference Proceedings
- Journal Volume
- 1581
- Journal Issue
- 1
- Journal Page Range
- p. 1861-1867
- ISSN
- 0094-243X
- CODEN
- APCPCS
Conference
- Title
- 40. annual review of progress in quantitative nondestructive evaluation; 10. international conference on Barkhausen noise and micromagnetic testing
- Dates
- 21-26 Jul 2013
- Place
- Baltimore, MD (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45085007
- Subject category
- S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COMPUTERIZED TOMOGRAPHY; FILMS; IMAGES; PHOTOLUMINESCENCE; SIMULATION; VALIDATION; X RADIATION; X-RAY TUBES
- Descriptors DEC
- DIAGNOSTIC TECHNIQUES; ELECTROMAGNETIC RADIATION; ELECTRON TUBES; EMISSION; EQUIPMENT; IONIZING RADIATIONS; LUMINESCENCE; PHOTON EMISSION; RADIATIONS; TESTING; TOMOGRAPHY; X-RAY EQUIPMENT
Optional Information
- Notes
- (c) 2014 AIP Publishing LLC