Cleanup and recovery of high TOC (Total Organic Carbon) D2O at Pickering NGS

Creators

  • 1. Ontario Power Generation - Pickering A (Canada)

Description

A process was developed in-house using readily available components from local vendors, pumps and storage tanks no longer used by the station. This process proved successful in bringing the total organic carbon (TOC) content of the D2O to an average of 3 ppm, which was then fed through the ion exchange cleanup system (IXCU) for final polishing and sent to the station upgrader as feed. It is estimated that this process has saved the station several million dollars in processing costs alone, based on an estimate from a contract company to clean up a small volume of the TOC contaminated D2O. The estimated value of the recovered D2O is approximately $54 million. (author)

Part of:
Good practices in heavy water reactor operation

Additional details

Publishing Information

ISBN
978-92-0-105710-5
Imprint Title
Good practices in heavy water reactor operation
Imprint Pagination
201 p.
Journal Page Range
p. 161-164
ISSN
1011-4289
Report number
IAEA-TECDOC--1650

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
41126190
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Descriptors DEI
CARBON; CONTRACTS; COST; HEAVY WATER; ION EXCHANGE; PROCESSING; STORAGE; TANKS
Descriptors DEC
CONTAINERS; DEUTERIUM COMPOUNDS; ELEMENTS; HYDROGEN COMPOUNDS; NONMETALS; OXYGEN COMPOUNDS; WATER