Published March 1984 | Version v1
Journal article

Plume rise from stacks with scrubbers: a state-of-the-art review

  • 1. Meteorological Institute, University of Hamburg, Hamburg, West Germany

Description

The state of the art of predicting plume rise from stacks with scrubbers is evaluated critically. The significant moisture content of the scrubbed plume upon exit leads to important thermodynamic effects during plume rise that are unaccounted for in the usual dry plume rise theories. For example, under conditionally unstable atmospheres, a wet scrubbed plume treated as completely dry acts as if the atmosphere were stable, whereas in reality the scrubbed plume behaves instead as if the atmosphere were unstable. Even the use of moist plume models developed for application to cooling tower plume rise is not valid since these models 1) employ the Boussinesq approximation, 2) use a number of additional simplifying approximations that require small exit temperature differences between tower exit and ambient temperatures, and 3) are not calibrated to stack data

Additional details

Publishing Information

Journal Title
Bull. Am. Meteorol. Soc.
Journal Volume
65
Journal Issue
3
Series
Bull. Am. Meteorol. Soc.
Journal Page Range
210-215
ISSN
0003-0007

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
16013936
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
COOLING TOWERS; ENVIRONMENTAL TRANSPORT; HUMIDITY; PLUMES; POLLUTION CONTROL EQUIPMENT; STACKS; SULFUR OXIDES
Descriptors DEC
CHALCOGENIDES; EQUIPMENT; MASS TRANSFER; OXIDES; OXYGEN COMPOUNDS; SULFUR COMPOUNDS