On the accuracy of implant dosimetry reconstructed from rotational stereoradiographs

Description

Stereo-shift implant reconstruction produces displacement errors when the shifts (S) are small (H/S>) relative to the focal spot-film distances (H). The authors investigated the errors using two films at 50 (S/H = 7), 100 (S/H = 4), 150 (S/H = 2.5), and 200 (S/H = 2) from a simulator and a commercial stereo reconstruction algorithm. Seven seeds on faces of an 8-cm cube served as the test object. Angles of 100, 16%, and 200 yielded errors of < 1 mm in the (x,y) coordinates and < 2 mm in the (z) coordinate

Additional details

Publishing Information

Publisher
Radiological Society of North America Inc.
Imprint Place
Oak Brook, IL (USA)
Imprint Title
Radiological Society of North America 73rd scientific assembly and annual meeting (Abstracts)
Journal Page Range
p. 69.

Conference

Title
73. scientific assembly and annual meeting of the Radiological Society of North America.
Dates
29 Nov - 4 Dec 1987.
Place
Chicago, IL (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
19083343
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S99: GENERAL AND MISCELLANEOUS;
Resource subtype / Literary indicator
Conference, Numerical Data
Descriptors DEI
ACCURACY; ALGORITHMS; DOSIMETRY; ERRORS; EXPERIMENTAL DATA; RADIATION SOURCE IMPLANTS; SIMULATION
Descriptors DEC
DATA; IMPLANTS; INFORMATION; NUMERICAL DATA; RADIATION SOURCES