Published 1987
| Version v1
Book
On the accuracy of implant dosimetry reconstructed from rotational stereoradiographs
Creators
Description
Stereo-shift implant reconstruction produces displacement errors when the shifts (S) are small (H/S>) relative to the focal spot-film distances (H). The authors investigated the errors using two films at 50 (S/H = 7), 100 (S/H = 4), 150 (S/H = 2.5), and 200 (S/H = 2) from a simulator and a commercial stereo reconstruction algorithm. Seven seeds on faces of an 8-cm cube served as the test object. Angles of 100, 16%, and 200 yielded errors of < 1 mm in the (x,y) coordinates and < 2 mm in the (z) coordinate
Additional details
Publishing Information
- Publisher
- Radiological Society of North America Inc.
- Imprint Place
- Oak Brook, IL (USA)
- Imprint Title
- Radiological Society of North America 73rd scientific assembly and annual meeting (Abstracts)
- Journal Page Range
- p. 69.
Conference
- Title
- 73. scientific assembly and annual meeting of the Radiological Society of North America.
- Dates
- 29 Nov - 4 Dec 1987.
- Place
- Chicago, IL (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19083343
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S99: GENERAL AND MISCELLANEOUS;
- Resource subtype / Literary indicator
- Conference, Numerical Data
- Descriptors DEI
- ACCURACY; ALGORITHMS; DOSIMETRY; ERRORS; EXPERIMENTAL DATA; RADIATION SOURCE IMPLANTS; SIMULATION
- Descriptors DEC
- DATA; IMPLANTS; INFORMATION; NUMERICAL DATA; RADIATION SOURCES