Quantifying the effects of iodine contrast media on standardised uptake values of FGD PET/CT images: an anthropomorphic phantom study
- 1. School of Medical Sciences, Bundoora Wast Campus, RMIT University, Victoria, Australia (Australia). Discipline of Medical Radiation
- 2. Faculty of Medicine and Health Sciences, University Putra Malaysia (UPM), Serdang, Malaysia (Malaysia). Nuclear Imaging Centre
- 3. The Alfred Hospital , Prahran, Victoria, Australia (Australia). William Buckland Radiotherapy Centre
- 4. The Alfred Hospital, Prahran, Victoria, Australia (Australia). Nuclear Medicine Dept.
Description
Full text: This study aimed to quantify the amount of change in Standardised Uptake Values (SUVs) of PET/CT images by simulating the set-up as closely as possible to the actual patient scanning. The experiments were co ducted using an anthropomorphic phantom, which contained an amount of radioactivity in the form of Fluorodeoxyglucose (FDG) in a primary plastic test tube and one litre saline bags, including the insertion of bony structures and another two test tubes containing different concentrations of iodine contrast media. Standard scanning protocols were employed for the PET/CT image acquisition. The highest absolute differences in the SUVmax and SUVmean values of the saline bags were found to be about 0.2 and 0.4, respectively. The primary test tube showed the largest change of 1.5 in both SUVs; SUV max and SUV-mean. However, none of these changes were found to be statistically significant. The clinical literature also contains no evidence to suggest that the changes of this magnitude would change the final diagnosis. Based on these preliminary data, we propose that iodine contrast media can be used during the CT scan of PET/CT imaging, without significantly affecting the diagnostic quality of this integrated imaging modality. (author)
Availability note (English)
Available in abstract form only, full text entered in this recordAdditional details
Publishing Information
- Journal Title
- Australasian Physical and Engineering Sciences in Medicine
- Journal Volume
- 34
- Journal Issue
- 3
- Journal Page Range
- p. 367-374
- ISSN
- 0158-9938
- CODEN
- AUPMDI
INIS
- Country of Publication
- Australia
- Country of Input or Organization
- Australia
- INIS RN
- 43108970
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CAT SCANNING; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; NUCLEAR MEDICINE; PATIENTS; PHANTOMS; POSITRON COMPUTED TOMOGRAPHY; RADIOACTIVITY; RADIOLOGY; THERAPY
- Descriptors DEC
- COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; MEDICINE; MOCKUP; NUCLEAR MEDICINE; STRUCTURAL MODELS; TOMOGRAPHY
Optional Information
- Notes
- 30 refs., 05 figs., 04 tabs.