Corrosion studies on PREPP waste form
Description
Deformation or Failure Test and Accelerated Corrosion Test procedures were conducted to investigate the effect of formulation variables on the corrosion of oversize waste in Process Experimental Pilot Plant (PREPP) concrete waste forms. The Deformation or Failure Test did not indicate substantial waste form swelling from corrosion. The presence or absence of corrosion inhibitor was the most significant factor relative to measured half-cell potentials identified in the Accelerated Corrosion Test. However, corrosion inhibitor was determined to be only marginally beneficial. While this study produced no evidence that corrosion is of sufficient magnitude to produce serious degradation of PREPP waste forms, the need for corrosion rate testing is suggested. 11 references, 4 figures, 8 tables
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01; 1 as DE84015169.
Files
Additional details
Additional titles
- Augmented title (English)
- Steel embedded in concrete
Publishing Information
- Imprint Pagination
- 42 p.
- Report number
- EGG-MS--6614
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16015195
- Subject category
- S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; S36: MATERIALS SCIENCE;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- CONCRETES; CORROSION; CORROSION INHIBITORS; DEFORMATION; EXPERIMENTAL DATA; FAILURES; LOW-LEVEL RADIOACTIVE WASTES; RADIOACTIVE WASTE PROCESSING; SOLID WASTES; SOLIDIFICATION; SWELLING
- Descriptors DEC
- BUILDING MATERIALS; CHEMICAL REACTIONS; DATA; INFORMATION; MANAGEMENT; MATERIALS; NUMERICAL DATA; RADIOACTIVE MATERIALS; RADIOACTIVE WASTES; WASTE MANAGEMENT; WASTE PROCESSING; WASTES