Published 1985 | Version v1
Report Restricted

AVR nuclear test power plant. 3. Quarterly report 1985 (1.7.1985 - 30.9.1985)

Description

Automatic translation: After eliminating a fault in the charging system at the beginning of the quarter, it only ran 3 times briefly when changing experiments interrupted power operation of the AVR power plant in the III. Quarter 1985 satisfactory, without significant impairments. The following operating data were achieved in the 3rd quarter of 1985: - time utilization 93.8% - work utilization 91.9% - Gross work el. 30453.4 MWh Further operating data as well as monthly overviews of the driven Performance can be seen in Figs. 1, 2 and 3.

Abstract (German)

Nach der Behebung einer Störung an der Beschickungsanlage zu Quartalsbeginn, verlief der lediglich zum Experimentwechsel 3 mal kurzzeitig unterbrochene Leistungsbetrieb des AVR-Kraftwerks im III. Quartal 1985 zufriedenstellend, ohne nennenswerte Beeinträchtigungen. Nachstehende Betriebsdaten wurden im 3. Quartal 1985 erreicht: - Zeitausnutzung 93,8 % - Arbeitsausnutzung 91,9 % - Bruttoarbeit el. 30453,4 MWh Weitere Betriebsdaten sowie monatliche Übersichten der gefahrenen Leistung sind den Abb. 1,2 und 3 zu entnehmen.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Original title (German)
AVR Atomversuchskraftwerk. 3. Quartalsbericht 1985 (1.7.1985 - 30.9.1985)

Publishing Information

Imprint Pagination
50 p.
Report number
INIS-DE--21M1399

Optional Information

Notes
Document from Juelich Preservation Project; 19 figs., 8 tabs.