Published January 1977 | Version v1
Report Open

Cryopump, neutral-beam compatibility test

Description

The design and performance testing plan for a cryopump to be used on the TFTR neutral beams injectors are briefly discussed. The cryopump consists of an outer envelope at liquid nitrogen temperature, and an inner envelope at liquid helium temperature. In the cryopanel-chevron structure to be tested, a deuterium condensation rate of 2.5 x 104 liters/s is predicted. A three phase test plan for performance testing at both LBL and LLL is delineated

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

9377348.pdf

Files (94.2 kB)

Name Size Download all
md5:0f2884bda6bcaa33a45804abd6ec8663
94.2 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
7 p.
Report number
LBL--5943

Conference

Title
American Nuclear Society annual meeting.
Dates
12 - 17 Jun 1977.
Place
New York, NY, USA.

Optional Information

Secondary number(s)
CONF-770611--30.